Jul 22, 2019

Assembly Complete - On To Testing

Soldering Finished



Visual Inspection

Check solder joints.
Check polarized capacitors.
Check diodes.
Check input ground.
Check output ground.
Check power ground

Gradual Start Up

Based on RobRob's amp start up procedure

Using current limiter into a variac.
Power up gradually with the rectifier.
Add the preamp tube.
Add the power tube.

Measure voltages and plate dissipation (see UncleDoug)

Powered On! Plugged In!